Ontario electrical code answers in plain words — with the rule number.
Ontario Code Check is a quick on-site reference for the Ontario Electrical Safety Code (OESC, 29th ed. 2024). Type the job in plain words — “plug near tub”, “panel in a closet”, “hot tub bonding” — and get a plain-language answer, the Ontario rule number that backs it up, and the one catch inspectors write up.
Open the app →Already use the app? Tap Open the app — one tap, just like before.
What's inside
Plain-language answers, with rule numbers
Checks for receptacles, panels, grounding and bonding, wiring methods, pools, EV chargers and more — for houses and for commercial and industrial jobs. Every answer names the OESC rule, so you can check it in the book.
The 24-item pre-inspection checklist
Built from the deficiencies ESA inspectors write up most often. Go through it before you call ESA and fix the easy ones first.
Ask a question
Type your full question the way you would ask it, and get a plain answer with the rule. Good for a quick check — you most likely know it; this backs you up.
ESA notes
Short plain notes on the topics ESA talks about a lot — EV charging, AFCI in renovations, pools and hot tubs, generators — with the rule each one is about.
Photo Check — a second set of eyes
Snap a photo of the work — a panel, a receptacle, your rough-in. Photo Check tells you what it can see, flags what to look at more closely with the code rule for each one, and lists what a photo can't tell you. A second look only — never a pass or a fail.
Who it is for
Made for Ontario electricians and apprentices on site — a fast second opinion in your pocket, in words you can read at arm's length. Homeowners doing their own permitted work can use it too, the same way: as a guide, never as a replacement for the code book or an inspection.
Try a real answer — free samples
These are full answers from inside the app, exactly as subscribers see them:
Can I run Teck cable to a hot tub in Ontario?Section 68 & Rule 12-012 How many circuits do you usually need in a kitchen?Rules 26-654, 26-656 & 26-722 Does a receptacle close to the tub or sink need GFCI protection?Rule 26-704 Where is AFCI protection required in a house?Rule 26-658 How deep does buried wiring have to be?Rule 12-012 & Table 53 How much clear space do you need in front of a panel?Rule 2-308 What size circuit does an EV charger need?Section 86 & Rule 8-104 What has to be bonded around a swimming pool?Rule 68-058These 8 are free samples. Inside the app you get all 74 checks, the Ask box — type any electrical question and get a plain-language answer with the rule number — and the 24-item pre-inspection checklist.
More code questions — short verdicts
These are samples. If you want the full capabilities of this app, please subscribe.
- Do kitchen counter receptacles need GFCI protection in Ontario?
- Do receptacles have to be tamper-resistant in Ontario?
- How far apart can receptacles be along a wall in a house?
- What protection does an outdoor receptacle need in Ontario?
- Can an electrical panel go in a clothes closet or bathroom?
- How detailed does panel labelling have to be?
- Is there a maximum height for the breakers in a panel?
- What decides the minimum service size for a house in Ontario?
- Can unused openings be left open in a panel or box?
- What qualifies as a grounding electrode in Ontario?
- What metal systems have to be bonded in a house?
- Does a hot tub need equipotential bonding like a pool?
- How are grounding and bonding conductor sizes picked?
- Can the incoming metal water pipe be the only ground for a service?
- How far from the edge of a stud must a drilled hole be?
- How many wires can fit in an electrical box?
- How close to a box must cable be stapled, and how often along the run?
- Does cable run across an attic need protection?
- What changes for wiring in a damp or wet location?
- When can I use NMD90, and when do I need NMWU?
- How close can a receptacle be to a swimming pool?
- What protection does a hot tub circuit need in Ontario?
- What does the Code require for connecting a standby generator?
- What are the rules for a home battery (energy storage) system?
- Do garage receptacles need GFCI protection or special placement?
- When is an ESA notification (permit) required in Ontario?
- What small electrical jobs don't need an ESA notification?
- Can wiring be covered with drywall or buried before inspection?
- Who can legally do electrical work for hire in Ontario?
- What is ESA's Authorized Contractor Program (ACP)?
- What happens after the final ESA inspection?
- What is different about a three-phase electrical service?
- How do you size feeders and services in a commercial building?
- What do you need to check when installing a transformer?
- How much clear space do big panels and switchgear need?
- What makes an electrical room acceptable in a commercial building?
- What marking is needed on commercial panels and equipment?
- What are the key rules for running EMT conduit?
- Where can armoured cable be used in a commercial building?
- What are the key rules for cable tray in a commercial building?
- How do you run and terminate Teck cable the right way?
- What is required when conduit or cable passes through a fire wall or floor?
- What has to be bonded in a commercial building?
- How is grounding different on a large commercial service?
- What do motors and rooftop HVAC units need for disconnects?
- What does an electrician need to know about fire alarm work?
- What do emergency lights have to do in a commercial building?
- What are the rules for exit signs in a commercial building?
- Does commercial electrical work need an ESA notification?
- How do inspections work on a commercial job?
- What changes for electrical work in a hazardous location?
- How close does a motor disconnect have to be to the motor?
- Why is the breaker for a motor so much bigger than the wire?
- Can you tap a feeder, or tap inside a service box?
- How do you protect a dry-type transformer and size its secondary conductors?
- What does ESA expect for CT metering on a commercial service?
- What changes for a standby generator on a commercial building?
- How is a fire pump fed electrically?
- Does a fire alarm panel need its own circuit?
- What do you need to get right for EV chargers in a parking garage?
- What does rooftop solar on a commercial building need electrically?
- What is different about electrical work over 750 V?
- Why is the floor of a vehicle repair garage a hazardous location?
- What is actually enforced for temporary power on a construction site?
- Does an electrical sign need its own disconnect?
- Can you start a tenant fit-up while the plans are with ESA?
Questions and answers
What is Ontario Code Check?
A quick on-site reference for the Ontario Electrical Safety Code (OESC, 29th edition, 2024). It turns common job questions into plain-language answers, each with the Ontario rule number that backs it up, plus the one catch inspectors write up most.
What's inside the app?
All 74 plain-language checks — residential and commercial/industrial — with rule numbers and ESA notes; the Ask box, where you type any electrical question and get a plain-language answer with the rule number; the 24-item pre-inspection checklist built from the deficiencies inspectors write up most; and Photo Check, where you snap a photo of the work and get a second look — what can be seen, flags with the code rule for each one, and what a photo can't tell you.
How much does it cost? Is there a free trial?
CAD $9.99/month, and the first month is free for new subscribers. After the free month it renews monthly at $9.99 until you cancel.
Does it work on iPhone and Android?
Yes — it works on iPhone and Android, and on a computer. Subscribe on this website, then open the app and sign in; you can add it to your home screen like an app.
Does one subscription cover my phone and my computer?
Yes. The subscription belongs to your account, not to one device. Sign in with the same account on your phone and your computer and both work.
How do I cancel?
Any time. Use "Manage subscription" in the app to open your subscription page and cancel there. You keep access until the end of the paid month — and if you cancel during the free month, you are not charged.
Does this replace the official code book?
No. Ontario Code Check is guidance only — a plain-language helper. Always check the real rule in the official Ontario Electrical Safety Code before you trust an answer, and remember the inspector has the last word. It is not an inspection.
Is Ontario Code Check affiliated with the ESA?
No. This app is an independent reference tool. It is not affiliated with, endorsed by, or approved by the Electrical Safety Authority (ESA).
One price. First month free.
CAD $9.99/month
- ✓ First month free for new subscribers
- ✓ Cancel anytime
- ✓ One account works on your phone and your computer
- ✓ Works on iPhone and Android
- ✓ Photo Check: snap a photo of your work and get a second look, with the rule for each flag